نتایج جستجو برای: transformer loss

تعداد نتایج: 456485  

Journal: :journal of advances in computer research 2016
s.mohammad bagher sadati jamal moshtagh abdollah rastgou

proper operations of transformer have several issues such as; preventing of unscheduled removal’s, increasing of reliability and continues supply of consumer demand. this result would be obtained that load and harmonic orders of sensitivity transformer at intervals appropriate for next hours and days is predicted to by selecting optimal utilization coefficient, reduction life of transformer is ...

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

2013
Yan Li Longnv Li Yongteng Jing Bo Zhang

In order to analyze the leakage magnetic field and stray loss in power transformer, leakage magnetic field and stray loss in structure parts of a power transformer are calculated by three-dimensional (3-D) non-linear time harmonic finite element method (FEM). The results show that stray loss and loss density in structure parts are large and which may lead to local overheating and affect perform...

Journal: :journal of artificial intelligence in electrical engineering 0

in this article, a multi-objective function for placement of distributed generation (dg) and capacitors with thetap setting of under load tap changer (ultc) transformer is introduced. most of the recent articles have paidless attention to dg, capacitor placement and ultc effects in the distribution network simultaneously. insimulations, a comparison between different modes was carried out with,...

2009
Xu Tang C. R. Sullivan Charles R. Sullivan

High-frequency loss in transformer windings using stranded wire is analyzed. A complete loss prediction method is presented. The interstrand resistivity, which is an important parameter to determine the power loss, is measured experimentally. The analytical model is solved to get an optimal pitch, which specifies the degree of twisting that results in minimum loss. A transformer using a strande...

2001

Significance: Dec 29, 2001 Identified By: NRC Item Type: FIN Finding DEGRADED AND INADEQUATELY TESTED TRANSFORMER AND PROTECTIVE RELAYING RESULTS IN INCREASE IN TRANSIENT AND LOSS OF OFFSITE POWER INITIATING EVENT FREQUENCIES On August 2, 2001, Unit 2 experienced a transformer failure, reactor scram, and loss of offsite power. The inspectors determined that a lightning strike in conjunction wit...

2001

Significance: Dec 29, 2001 Identified By: NRC Item Type: FIN Finding DEGRADED AND INADEQUATELY TESTED TRANSFORMER AND PROTECTIVE RELAYING RESULTS IN INCREASE IN TRANSIENT AND LOSS OF OFFSITE POWER INITIATING EVENT FREQUENCIES On August 2, 2001, Unit 2 experienced a transformer failure, reactor scram, and loss of offsite power. The inspectors determined that a lightning strike in conjunction wit...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی خواجه نصیرالدین طوسی - دانشکده مهندسی برق و کامپیوتر 1391

power transformers are important equipments in power systems. thus there is a large number of researches devoted of power transformers. however, there is still a demand for future investigations, especially in the field of diagnosis of transformer failures. in order to fulfill the demand, the first part reports a study case in which four main types of failures on the active part are investigate...

2013
Jin Wang Zhongping Yang Fei Lin

The traction transformer of the traction drive system of a high-speed train is one of the main equipments for energy conversion. The transformer loss will be increased by load harmonics and pantograph arcs at high speed. It is very important to predict losses for the improvement of traction transformer design. In this paper, a dynamic model of the pantograph-catenary system is established using...

2003
John H. Brunke Klaus J. Fröhlich

Transformer inrush currents are highmagnitude, harmonic-rich currents generated when transformer cores are driven into saturation during energization. These currents have undesirable effects, including potential damage or loss-of-life to the transformer, protective relay misoperation, and reduced power quality on the system. Controlled transformer switching can potentially eliminate these trans...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید